USE OF PAINT FILTER LIQUIDS TEST TO DETERMINE FREE LIQUIDS IN A WASTE
•
CORROSIVE CHARACTERISTIC APPLIED TO LIQUID AND AQUEOUS WASTES
•
IGNITABILITY OR CORROSIVITY TESTING-LIQUID AND AQUEOUS DEFINITION
•
APPLICABILITY OF CORROSIVITY PH AND STEEL CORROSION TESTS
•
DEFINITION OF A LIQUID AS IT APPLIES TO IGNITABLE AND CORROSIVE WASTES; LIQUID
AS IT APPLIES TO IGNITABLE OR CORROSIVE WASTES
•
PH MEASUREMENT ON PARTIAL SOLIDS
Regulations for Steel Corrosivity
§ 261.22(a)
(2) It is a liquid and corrodes steel (SAE 1020) at a rate greater than 6.35 mm (0.250 inch) per
year at a test temperature of 55 °C (130 °F) as determined by Method 1010A in "Test Methods
for Evaluating Solid Waste, Physical/Chemical Methods," EPA Publication SW–846, and as
incorporated by reference in §260.11 of this chapter.
Letters/Memoranda
• SW-846 TEST METHODS
• AGITATE SAMPLES EVALUATED USING METHOD 1110
•
SPENT PICKLE LIQUOR CORROSIVITY
Regulations for the Hazardous Waste Number for Corrosivity
§ 261.22
(b) A solid waste that exhibits the characteristic of corrosivity has the EPA Hazardous Waste
Number of D002.
[45 FR 33119, May 19, 1980, as amended at 46 FR 35247, July 7, 1981; 55 FR 22684, June 1,